Filter Results By:

Products

Applications

Manufacturers

Insulation Test

Check of a materials ability to prevent or reduce transmission.

See Also: Impulse Winding Testers


Showing results: 406 - 420 of 427 items found.

  • Elongation Tester

    SC-5 - Shanghai Dean Electrical Co., Ltd

    Executive standard: GB/T4074.3-2008/IEC60851-3; Inspection standard: JB/T4279.3-2008Used to test elongation (ductility) of copper wires covered with φ0.100-3.0 mmenamel, silk or other insulation materials and other metal wires with tensile strength ≤2000N;Application of SCM control allows for fast operation and strong anti-interference capacity;Preset elongation of samples with two-digit toggle switch and, when the preset value is reached during test, motor and counter would automatically stop action and display results;The instrument is capable of measuring elongation while also the tensile force and holding the maximum tensile force value during stretching;Clamps are designed according to characteristics of various wires to prevent samples from breaking at clamp jaws, easy to load samples and, after samples are compressed, enamel can be automatically broken;While sample is broken, movable clamp would automatically stop moving, with error between displayed and actual elongation value less than 1%;

  • Connector Test

    Applied Relay Testing Ltd.

    A connector test system which provides expansion of up to 160 Kelvin pair connections. The system incorporates high voltage AC and DC power supplies with a maximum output of +/- 2100 Volts peak for Hi Pot, Insulation resistance measurement. LCR bridge control is provided with 4 terminal multiplexing in order to add precision capacitance, inductance and resistance measurement capability. An integral H.V. capacitor bias option permits capacitance measurement to be made at up to 2.1kV.

  • Battery Pack Rotate Test Device

    Guangdong Bell Experiment Equipment Co.,Ltd

    DGBell's Battery Pack Rotate Test Device Single storage cell safety testTest object: Battery storage pack or systemRotate the battery pack 360°around X axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Rotate the batter pack 360°around Y axis with rotation speed of 6°/s; secondly rotate it 90°,180°,270°,360°,and remain for one hour after each move. Then stop and observe for 2 hours.Accept standard: Battery pack or system has no electrolyte leakage, no rupture at case, no fire nor explosion. And remain the connection reliable, the structure intact, the insulation resistance value not less than 100 Omega /v.

  • Multifunction Electrical Installations Meter

    MPI-520 - Sonel S.A.

    The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.

  • Fuel Quantity Testers

    Barfield Inc.

    Fuel capacitance systems are separated into two broad groupings, AC capacitance and DC capacitance. The source of these names derives from the type of signal processed by the fuel system amplifier. Barfield designs a universal tester for each type of system with the proper interface harnesses to access individual aircraft applications. Some of the various test and measurements include:*Insulation - Testing the wiring and probes*Fuel Tank Capacitance Measurement*Individual Probe Capacitance Measurement*Capacitance Simulation - Indicators and amplifiers*Indicators - Bench testing of remote units

  • AC Motor Tester

    AIP892X series - Qingdao AIP Intelligent Instruments Co., Ltd

    This product is suitable for electrical performance testing of all types of motors, such as home appliance motors (washing machines, air conditioners, fans, etc.), pump motors, stepper motors, etc. One-stop testing completes all set items, stable, fast, efficient and accurate, widely used by domestic and foreign enterprises.This AC motor tester test items: AC Hi-pot, insulation resistance, surge, DC winding resistance, no-load characteristics, low voltage start, locked rotor, rotation, PG characteristics.

  • *High Current Switches

    B-1002 - Ruetz Technologies GmbH

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Current Switches

    B-1002 - ROSS ENGINEERING CORPORATION

    Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force.  Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz.  Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit.  Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas.  For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.

  • High Voltage Grounding Relays

    B-1007 - ROSS ENGINEERING CORPORATION

    Extra high voltage, low corona, grounding relays of the air insulated type.  Peak test ratings up to 300kV and 100 amps continuous.  Units can be operated either by solenoid, motor, or air cylinder, with spring or gravity return.  All models have spherical contacts.  When voltage transient limiting is required, some models have an adjustable sphere gap.  Also available are units with built-in high voltage discharge resistors with energy dissipation capabilities from 50 to 10,000 ohms.  Some units can be reduced in height if full line to ground voltage is connected to the top high voltage contact only and the other high voltage terminal is operating at, or near, ground potential.  Line to ground voltage can also be increased by adding insulation between lower high voltage contact and ground.  Normally mounted base down.  Base up mounting if specified.

  • Multifunction Instrument

    COMBI521EV - HT Italia Srl

    COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • AC Ground Bond Tester

    446 - SCI

    Our 446 model is a 4-in-1 tester with AC Hipot, DC Hipot, Insulation Resistance, and Ground Bond capabilities. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application. The 446 is equipped with multiple memories and an optional USB port for remote BUS communication so you can quickly perform tests on a variety of DUTs from the front panel or with a PC. Add to user safety by equipping your tester with Personal Protective Equipment (PPE) via the built-in safety interlock.

  • Portable Line Tester

    DR-5 - Daerim Electronics Co.

    The DR-5 is designed for repairing line faults and installing new telephone lines, especially for the MDF in unmanned offices which do not have their own test board.1. Insulation resistance measuring2. Loop resistance measuring3. DC voltage measuring4. Terminal, Line capacity measuring5. Subscriber calling6. Dialing(Tone, Pulse type)7. Transmitting, receiving, waiting, and three way calling8. Test tone transmitting9. Four type melody soundInsulation resistance measuring range: DC180V / 50Mega OhmLoop resistance measuring range : 0 ~ 500Kilo OhmDC voltage measuring range : 0 ~ 150VRing signal Range : 20Hz / 75VPower : DC12V, AC 85~260 Free voltageDimension : 330 * 220 * 140(m/m)Weight : 3.5kg

  • DC High-Voltage Test Device

    PGK 80 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • DC High-Voltage Test Device

    PGK 50 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 50. The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

  • Installation Safety Testers

    PeakTech Prüf- und Messtechnik GmbH

    This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.

Get Help